Home
Chi siamo
Prodotti
Scaricare
Biblioteca tecnica
Contatto
Richiesta
Mappa del sito 
Collegamenti
 

Allarme & Cavo Audio & Elettronico

Cavo di Equivalente di Belden

Cavo coassiale

Cavo di Controllo

Cavo Fibra Ottica

Cavo Flessibile

Cavo strumentazione

Cavi LAN
Cavo Energia
CavoFerroviario

Robotic

Cavo per Materiale Rotabile
Cavo di gomma
Cavo di Sicurezza

Cavo Telefonico

Aeroporto Cavo

Bus Cavo

Serracavi

Data Cable

Calore di rilevamento Cavo
Cavo ad alta temperatura
Cavo autostrada
Marine, petrolio, gas e petrolchimico Cavo
Cavo Speciali
Cavo a spirale
Termocoppia Cavo
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Cavo telefonico

 Foam Skin Insulated & AP Sheathed (ALPETH) Jelly Filled Cables to GR-421

image of Foam Skin Insulated & AP Sheathed (ALPETH) Jelly Filled Cables to GR-421

Applicazione

The cables are designed for use in access or trunk networks, from telephone exchange to subscriber area. The cables are suitable for installation in ducts, direct burial in the ground and also for aerial installation with integral suspension strand.Jelly filled option is for subscriber’s cables installed underground or along the edge of pavement. An armoured option is offered for direct burial installations where additional mechanical or rodent protection is required. A figure-8 self support option is offered for aerial installation.

Norme

construction of Foam Skin Insulated & AP Sheathed (ALPETH) Jelly Filled Cables to GR-421

• Telcordia (Bellcore) GR-421

 

 

 

Costruzione

Conduttori
Solid annealed bare copper, 0.4/0.5/0.63/0.9mm as per ASTM B-3/class 1 of IEC 60028

Isolamento
Foam Skin which is a composite polyethylene insulation made of an inner cellular layer and an outer solid skin as per ASTM D 1248/IEC 60708

Coppie intrecciate
Insulated conductors are twisted into pairs with varying lay length to minimize crosstalk

Elemento di cablaggio
Twisted Pairs

Cavo Core Assemblea
Cables with up to 400 pairs are composed of 25-pair units or 12/13-pair units; cables with over 400 pairs are composed of 50 or 100-pair units. Any extra pairs form a separate unit. Units are identified by colour coded binders. Standard construction is per GR-421 given in Cable Make Up Diagram

Core Wrapping(optional)
One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap. These tapes furnish thermal, mechanical as well as high dielectric protection between shielding and individual conductors

Umidità Barriera
A layer of bare aluminium tape (0.2mm/8mil) is applied longitudinally with overlap over the cable core to provide 100% electrical shielding coverage and ensures a barrier against water vapor. In cables with more than 200 pairs, the aluminum tape may be corrugated for improved cable flexibility

Riempimento
The cable core interstices are filled with petroleum jelly to avoid longitudinal water penetration within the cable.
The water resistant filling compound is applied to the air space between non-hygroscopic tape and shield, shield and sheath within the cable core

Guaina
Black low density polyethylene as per ASTM D 1248/IEC 60708, being able to withstand exposure to sunlight,
temperature variations, ground chemicals and other environmental contaminants

Ripcord(optional)
Ripcord may be provided for slitting the sheath longitudinally to facilitate its removal

Spare Pairs (optional)
Spare pairs may be incorporated for large pair cables

Filo di continuità (optional)
One tinned copper drain wire may be longitudinally laid to ensure electrical continuity of the screen

armoured telephone cables armoured telephone cables

Opzionale Costruzione

Cavo armato
Steel wire armour or corrugated steel tape armour applied over an optional inner polyethylene sheath.For steel tape version, the 0.15mm/6mil thick steel tape is coated with a copolymer and applied with an overlap. An outer polyethylene sheath is applied over the armour

Self-Support Cavi
A 7-strand galvanized steel strand is used as support wire. Black polyethylene sheath covers both core and support wire in a figure-8 construction

Proprietà elettriche

Nominal Conductor Diameter

mm

0.4

0.5

0.63

0.9

Conductor Gauge Size

AWG

26

24 22

19

Maximum Average DC Resistance

Ω/km / Ω/mile

140/225

87/140 55/88.6

27.0/43.4

Maximum Individual DC Resistance

Ω/km / Ω/mile

144.2/232

89.5/144 56.5/91.0

28.0/45.0

Minimum Insulation Resistance @500V DC

MΩ.km / MΩ.mile

1600/1000

1600/1000 1600/1000

1600/1000

Maximum Average Resistance Unbalance

%

1.5

1.5 1.5

1.5

Maximum Individual Resistance Unbalance

%

5

5 5

5

Average Mutual Capacitance

nF/km / nF/kft

48.5-54.0
/14.8-16.5

48.5-54.0
/14.8-16.5
48.5-54.0
/14.8-16.5

48.5-54.0
/14.8-16.5

Maximum Individual Mutual Capacitance

nF/km / nF/kft

57/17.4

57/17.4 57/17.4

57/17.4

Maximum Individual Capacitance Unbalance pair-to-pair

pF/km / pF/kft

145/44

145/44 145/44

145/44

Capacitance Unbalance RMS pair-to-pair

pF/km / pF/kft

45/13.7

45/13.7 45/13.7

45/13.7

Maximum Individual Capacitance Unbalance pair-to-ground

pF/km / pF/kft

2625/800

2625/800 2625/800

2625/800

Maximum Average Capacitance Unbalance pair-to-ground

pF/km / pF/kft

574/175

574/175 574/175

574/175

Maximum Conductor Loop Resistance @20°C

Ω/km / Ω/mile

300/482

192/309 114/183.6

60/96.4

Impedance @1KHz

994

796 660

445

Impedance @100KHz

147

134 125

122

Impedance @512KHz

120

118 117

116

Impedance @1MHz

117

115 114

113

Maximum Average Attenuation @0.8KHz

dB/km / dB/kft

1.64/0.5

1.30/0.39 1.04/0.32

0.74/0.22

Maximum Average Attenuation @1KHz

dB/km / dB/kft

1.68/0.51

1.35/0.41 1.08/0.33

0.76/0.23

Maximum Average Attenuation @3KHz

dB/km / dB/kft

3.18/0.97

2.52/0.77 2.01/0.61

1.42/0.43

Maximum Average Attenuation @150KHz

dB/km / dB/kft

11.4/3.47

8.3/2.53 6.2/1.89

4.4/1.34

Maximum Average Attenuation @772KHz

dB/km / dB/kft

24.3/7.4

19.4/5.9 15.4/4.7

10.8/3.3

Maximum Average Attenuation @1000KHz

dB/km / dB/kft

27.1/8.25

21.4/6.52 17.5/5.33

12.8/3.89

Dielectric Strength

Conductor to Conductor (3secs)

V DC

2400

3000

4000

5000

Conductor to Screen (3secs)

V DC

10000

10000

10000

10000

1 2